FSP750C-A · 3/4 HP

Automatic Pool Cover & Utility Pump

Automatic control. Two-surface setup.

$89.99 USD In stock
FLUENTPOWER FSP750C-A automatic utility pump with removable wide strainer base, outlet adapters and rope

Check your fit: Automatic low-level drainage from pool covers, clean hard surfaces, pools, hot tubs and similar collected-water areas where the pump can remain upright.

Free standard shipping to eligible U.S. addresses.

Usually ships in 1–2 business days.

Estimated delivery: 3–5 business days after dispatch.

Shipping policy

An automatic submersible pump for pool-cover water removal and everyday utility drainage, with capacitive water sensing and a removable wide strainer base. Use the base on flexible pool covers; remove it for clean water on a hard, level surface.

$89.99 USD

In stock

Free standard shipping to eligible U.S. addresses.
Usually ships in 1–2 business days.
Estimated delivery: 3–5 business days after dispatch. Shipping policy.

3,400MAX GPH
29.5 ftMAX HEAD
2.7 / 0.4 inON / OFF
Capacitive automatic start / stop 26.2 ft power cord Confirm outlet connection before use

ONE PUMP.
TWO SURFACE MODES.

Install the wide strainer base for stability on a flexible pool cover or softer surface. On clean water over a hard, level surface, remove the base for a more compact low-level setup.

FSP750C-A draining pool-cover, pool, indoor and outdoor standing water

FSP750C-A / PRODUCT VIDEOS

Watch it work.

See the setup. See it in use.

FSP750C-A with the wide strainer base installed and removed
MODE 01 · BASE INSTALLED

STABILITY FOR FLEXIBLE OR SOFTER SURFACES.

Fit the wide strainer base on a pool cover or another surface that can shift under the water load. The wider footprint helps the pump remain upright.

FSP750C-A pump and removable strainer base dimensions
MODE 02 · BASE REMOVED

COMPACT LOW-WATER SETUP ON A HARD, LEVEL SURFACE.

Remove the base only for clean-water use where the pump can stand securely. Check the dimensional view before placing it in a confined area.

Choose the hose end first.

Pick the connection family that matches the hose or pipe you already plan to use. The full five-path manual diagram remains available below for confirmation.

CURRENT SUPPLIED OUTLINED MANUAL · PAGE 2
01
MOST COMMON HOSE ROUTES

STRAIGHT ADAPTER

Use the stepped adapter for a standard garden hose, 1 in threaded connection or 1-1/4 in plain hose.

A
3/4 in GHTGarden-hose thread connectionMANUAL REF P2-A
B
1 in NPTNPT threaded connectionMANUAL REF P2-B
C
1-1/4 in IDPlain hose inner diameter + clampMANUAL REF P2-C
Manual line drawing of the FSP750C-A straight stepped adapter
02
HIGH-FLOW / FIXED-PIPE ROUTES

1-1/2 IN NPT ADAPTERS

Choose the elbow to redirect the outlet or the straight fitting for an inline 1-1/2 in NPT connection.

D
1-1/2 in NPTElbow-adapter connectionMANUAL REF P2-D
E
1-1/2 in NPTStraight-adapter connectionMANUAL REF P2-E
Manual line drawings of the FSP750C-A 1-1/2 inch NPT elbow and straight adapters
View the full five-path connection diagramMANUAL PAGE 2
FSP750C-A connection diagram with three straight-adapter hose paths and two 1-1/2 inch NPT adapter paths
FULL CONNECTION DIAGRAM · CURRENT SUPPLIED OUTLINED MANUAL PAGE 2

FIELD NOTEThe manual shows five hose paths across the supplied straight, elbow and threaded adapters. Match both the nominal size and thread standard; use a clamp only with the 1-1/4 in ID plain-hose path.

Verified product details.

Specifications and automatic start/stop water levels below follow the U.S. version of the FSP750C-A manual.

U.S. MANUAL · FSP750C-A
POWER3/4 HP
MAX FLOW3,400 GPH
MAX HEAD29.5 ft
MAX SOLIDS0.4 in
POWER SUPPLY115V / 60Hz
MAX CURRENT3.83 A
CONTROLCapacitive water sensing
POWER CORD26.2 ft
STARTING WATER LEVELApprox. 2.7 in
STOP TRIGGER WATER LEVELApprox. 0.4 in; stops after 20 sec
DISCHARGE PORTStraight or elbow adapter routes
DRY-RUN PROTECTIONAutomatic retry + lockout
BASERemovable wide strainer
MODELFSP750C-A

Flow changes with lift.

The supplied manual lists five approximate flow points. Actual output depends on total lift, hose diameter, hose length and routing losses.

SOURCE→PUMP→OUTLET
LIFT HEIGHTFLOW RATE
3.3 ft3,300 GPH
6.6 ft3,060 GPH
13.1 ft1,580 GPH
20 ft1,320 GPH
26.3 ft420 GPH

Know the use limits.

Use the pump only within the operating and placement limits stated in the current supplied manual.

REQUEST THE CURRENT MANUAL
FIT

Automatic low-level drainage from pool covers, clean hard surfaces, pools, hot tubs and similar collected-water areas where the pump can remain upright.

NOT FIT

Do not place the pump in mud, sand or loose debris. Do not suspend it by the power cord or discharge hose, and do not use it where people are present in the water. Use a grounded GFCI-protected 115V supply.

WARRANTY

Coverage is subject to the terms in the current supplied manual; no duration is stated in the reviewed pages.

SAME JOB · DIFFERENT FIT

COMPARE SIMILAR PUMPS.

Stay within the same pump family, then compare control method, connection and installation fit.